Skip to content
HitLight
Robert Juliat · Spot

Robert Juliat Lucy

DMX chart, 4 DMX modes and a 3D preview. 2 / 3 / 4 DMX channels.

What it can do

  • Dimmer

Safety-relevant functions: Lamp on and off · Fixture reset. Check how these behave on your own fixture before a show.

DMX modes and channel charts

DMX modes of Robert Juliat Lucy
ModeChannelsIn HitLight
Mode 1 - Local disabled required2Ready in HitLight
Mode 2 - Local disabled required3Ready in HitLight
Mode 3 - Local disabled required3Ready in HitLight
Mode 4 - Local disabled required4Ready in HitLight

Mode 1 - Local disabled required

Ready in HitLight

2 DMX channels · Download this chart as CSV

DMX channel chart for Mode 1 - Local disabled required
ChannelFunctionDefaultDMX values
1Control0
22 value ranges
  • 0–0 Value 0 (no command; value 0 is required to activate a second function)
  • 1–133 Not printed in the chart (1-133)
  • 134–134 Dimmer Test (hold 3 seconds)
  • 135–135 Dimmer Reset (hold 3 seconds)
  • 136–143 Not printed in the chart (136-143)
  • 144–144 CONTROL BOARD Test (hold 3 seconds)
  • 145–145 CONTROL BOARD Reset (hold 3 seconds)
  • 146–149 Not printed in the chart (146-149)
  • 150–150 RJNET Reset (hold 3 seconds)
  • 151–219 Not printed in the chart (151-219)
  • 220–220 Local command = ON (hold 3 seconds)
  • 221–224 Not printed in the chart (221-224)
  • 225–225 Local command = OFF (DMX only) (hold 3 seconds)
  • 226–229 Not printed in the chart (226-229)
  • 230–230 Feedback flash light = OFF (hold 3 seconds)
  • 231–234 Not printed in the chart (231-234)
  • 235–235 Feedback flash light = ON (hold 3 seconds)
  • 236–239 Not printed in the chart (236-239)
  • 240–240 Backlight off-time = OFF (hold 3 seconds)
  • 241–244 Not printed in the chart (241-244)
  • 245–245 Backlight off-time = ON (hold 3 seconds)
  • 246–255 Not printed for the 1200 W Lucy (250 Lamp OFF / 255 Lamp ON apply to the 1800W model only)
2Dimmer00–255

Mode 2 - Local disabled required

Ready in HitLight

3 DMX channels · Download this chart as CSV

DMX channel chart for Mode 2 - Local disabled required
ChannelFunctionDefaultDMX values
1Control0
22 value ranges
  • 0–0 Value 0 (no command; value 0 is required to activate a second function)
  • 1–133 Not printed in the chart (1-133)
  • 134–134 Dimmer Test (hold 3 seconds)
  • 135–135 Dimmer Reset (hold 3 seconds)
  • 136–143 Not printed in the chart (136-143)
  • 144–144 CONTROL BOARD Test (hold 3 seconds)
  • 145–145 CONTROL BOARD Reset (hold 3 seconds)
  • 146–149 Not printed in the chart (146-149)
  • 150–150 RJNET Reset (hold 3 seconds)
  • 151–219 Not printed in the chart (151-219)
  • 220–220 Local command = ON (hold 3 seconds)
  • 221–224 Not printed in the chart (221-224)
  • 225–225 Local command = OFF (DMX only) (hold 3 seconds)
  • 226–229 Not printed in the chart (226-229)
  • 230–230 Feedback flash light = OFF (hold 3 seconds)
  • 231–234 Not printed in the chart (231-234)
  • 235–235 Feedback flash light = ON (hold 3 seconds)
  • 236–239 Not printed in the chart (236-239)
  • 240–240 Backlight off-time = OFF (hold 3 seconds)
  • 241–244 Not printed in the chart (241-244)
  • 245–245 Backlight off-time = ON (hold 3 seconds)
  • 246–255 Not printed for the 1200 W Lucy (250 Lamp OFF / 255 Lamp ON apply to the 1800W model only)
2Dimmer00–255
3Dimmer Fine0Fine byte of Dimmer

Mode 3 - Local disabled required

Ready in HitLight

3 DMX channels · Download this chart as CSV

DMX channel chart for Mode 3 - Local disabled required
ChannelFunctionDefaultDMX values
1Control0
22 value ranges
  • 0–0 Value 0 (no command; value 0 is required to activate a second function)
  • 1–133 Not printed in the chart (1-133)
  • 134–134 Dimmer Test (hold 3 seconds)
  • 135–135 Dimmer Reset (hold 3 seconds)
  • 136–143 Not printed in the chart (136-143)
  • 144–144 CONTROL BOARD Test (hold 3 seconds)
  • 145–145 CONTROL BOARD Reset (hold 3 seconds)
  • 146–149 Not printed in the chart (146-149)
  • 150–150 RJNET Reset (hold 3 seconds)
  • 151–219 Not printed in the chart (151-219)
  • 220–220 Local command = ON (hold 3 seconds)
  • 221–224 Not printed in the chart (221-224)
  • 225–225 Local command = OFF (DMX only) (hold 3 seconds)
  • 226–229 Not printed in the chart (226-229)
  • 230–230 Feedback flash light = OFF (hold 3 seconds)
  • 231–234 Not printed in the chart (231-234)
  • 235–235 Feedback flash light = ON (hold 3 seconds)
  • 236–239 Not printed in the chart (236-239)
  • 240–240 Backlight off-time = OFF (hold 3 seconds)
  • 241–244 Not printed in the chart (241-244)
  • 245–245 Backlight off-time = ON (hold 3 seconds)
  • 246–255 Not printed for the 1200 W Lucy (250 Lamp OFF / 255 Lamp ON apply to the 1800W model only)
2Motorized dimmer shutter00–255
3Dimmer Master maximum cap2550–255

Mode 4 - Local disabled required

Ready in HitLight

4 DMX channels · Download this chart as CSV

DMX channel chart for Mode 4 - Local disabled required
ChannelFunctionDefaultDMX values
1Control0
22 value ranges
  • 0–0 Value 0 (no command; value 0 is required to activate a second function)
  • 1–133 Not printed in the chart (1-133)
  • 134–134 Dimmer Test (hold 3 seconds)
  • 135–135 Dimmer Reset (hold 3 seconds)
  • 136–143 Not printed in the chart (136-143)
  • 144–144 CONTROL BOARD Test (hold 3 seconds)
  • 145–145 CONTROL BOARD Reset (hold 3 seconds)
  • 146–149 Not printed in the chart (146-149)
  • 150–150 RJNET Reset (hold 3 seconds)
  • 151–219 Not printed in the chart (151-219)
  • 220–220 Local command = ON (hold 3 seconds)
  • 221–224 Not printed in the chart (221-224)
  • 225–225 Local command = OFF (DMX only) (hold 3 seconds)
  • 226–229 Not printed in the chart (226-229)
  • 230–230 Feedback flash light = OFF (hold 3 seconds)
  • 231–234 Not printed in the chart (231-234)
  • 235–235 Feedback flash light = ON (hold 3 seconds)
  • 236–239 Not printed in the chart (236-239)
  • 240–240 Backlight off-time = OFF (hold 3 seconds)
  • 241–244 Not printed in the chart (241-244)
  • 245–245 Backlight off-time = ON (hold 3 seconds)
  • 246–255 Not printed for the 1200 W Lucy (250 Lamp OFF / 255 Lamp ON apply to the 1800W model only)
2Motorized dimmer shutter00–255
3Motorized dimmer shutter Fine0Fine byte of Motorized dimmer shutter
4Dimmer Master maximum cap2550–255

Use the Robert Juliat Lucy in HitLight

  1. Open Add fixture and search for Robert Juliat Lucy.
  2. Choose the DMX mode set in the fixture’s own menu. HitLight gives it the lowest free start address on its universe that fits the mode’s channel count.
  3. Check the mode and controls against your real fixture before live use.

Venues with the Robert Juliat Lucy

Their saved rigs list this fixture model. Confirm the current equipment with the venue.

Charts come from the fixture’s GDTF description as converted for the HitLight library. HitLight is not affiliated with Robert Juliat.

Fixture model: gdtf-robert-juliat-lucy-2611131301
Creator: HitLight
Modifications: Original HitLight 3D housing: scripted parametric geometry modelled by HitLight from public product photos and the manufacturer's published dimensions. No manufacturer imagery, CAD, meshes or GDTF models are redistributed.

Patch it, then let the music run the lights.

HitLight finds these fixtures in its library, patches them on the next free address and previews your rig in 3D before a single light is plugged in.

Open HitLight ↗Download HitLight