Elgiva Theatre
Main room. 57 saved fixture records. Explore the room inventories, source references and available planning resources.
Unofficial page Built by HitLight from public sources. Not yet confirmed by Chipping Norton Theatre. Is this your venue? Claim, edit or remove this pageClaim or remove this page ↗
Take the rig with you
This room can’t be opened in HitLight yet. An editable copy will be available after this rig’s public-copy review. You can still explore it in 3D and download the free files.
Unofficial page Built by HitLight from public sources. Not yet confirmed by Chipping Norton Theatre. Is this your venue? Claim, edit or remove this pageClaim or remove this page ↗
Chipping Norton Theatre is a venue in Chipping Norton, United Kingdom. Its HitLight preview contains 72 source-based fixture records. It displays 68 approximate catalogue housings; 4 records still use labelled visual fallbacks. The current installation, dimensions, installed modes and DMX patch require confirmation with the venue.
Choose your room or lighting configuration. PDF downloads are free and need no account. Download files retain their original language and content.
House rig · 72 documented fixture records
Main room: 72 fixture records in this saved partial reconstruction. Catalogue-matched entries include 12 × ETC Source Four jr Zoom, 8 × ETC Source Four PARNel, 5 × Showtec Shark Zoom Wash. 43 records use visual placeholders; fixture identity or mode still needs verification. Confirm the current configuration and patch with the venue.
Venue sources and document dates · Link to this room’s lighting information · Report a correction for this room ↗
Orbit, pan and zoom through the lighting rig. Fixture bodies are approximate.
72 fixture records in this saved reconstruction. This is a documented subset and may include provisional matches; it is not the venue’s complete equipment stock.
| Manufacturer | Fixture | Mode | Count |
|---|---|---|---|
| ETC | Source Four jr Zoom · DMX chart | Mode unverified | 12 |
| ETC | Source Four PARNel · DMX chart | Mode unverified | 8 |
| ETC | Source Four Zoom 15-30 · DMX chart | Mode unverified | 4 |
| Showtec | Shark Zoom Wash · DMX chart | Patch unverified | 5 |
| Visual placeholder | Acclaim F / ADB F (650W) | Unverified; visual substitute | 12 |
| Visual placeholder | Acclaim PC / ADB PC (650W) | Unverified; visual substitute | 10 |
| Visual placeholder | ADB A59 25/50 | Unverified; visual substitute | 1 |
| Visual placeholder | Par 64 CP62 | Unverified; visual substitute | 8 |
| Visual placeholder | Quartet Fresnel | Unverified; visual substitute | 2 |
| Visual placeholder | Showtec Slimline 12Q5 Batten | Unverified; visual substitute | 2 |
| Visual placeholder | Source 4 Par MFL | Unverified; visual substitute | 8 |
The source check date records when the reference was reviewed; it does not certify that the installed rig is unchanged.
Spot something that needs updating? Report a correction ↗
HitLight presents a source-based reconstruction of the documented room configuration. Fixture counts describe records in the saved reconstruction, not a verified count of the venue’s current equipment. Catalogue matches identify the profiles used in that reconstruction; they do not independently verify the installed model or DMX mode. Visual placeholders remain provisional.
The 3D view uses approximate fixture bodies. Positions, scale, heights and aiming may include estimates. A downloaded HitLight fixture plot is a planning resource, not an official venue drawing or a rigging specification. A DMX patch CSV is listed only when its source reconciliation has been reviewed.
Read the source references and their document dates, then confirm the room, configuration, equipment availability and patch with the venue before use. A source check date records a document review; it does not certify an unchanged installation. HitLight’s reconstruction does not imply venue endorsement.
Yes. Choose your room in the Chipping Norton Theatre fixture plot PDFs above. These HitLight lighting plans are free to download without an account.
This entry does not include a verified DMX patch file. The fixture plots document the reconstructed fixture positions; confirm DMX addresses and modes with the venue before use.
Working from another technical rider or patch sheet? Read about importing a lighting plot and setting DMX addresses.
This page is not run by Chipping Norton Theatre. If you work there, claim it to keep it accurate, or ask us to remove it. When a venue asks, we take its page down within two working days.
Claim or remove this page ↗Help keep this page useful. Send your role, the exact room and configuration, any equipment or patch corrections, and a public technical document with its date. We review the evidence before changing the published information.
Send a technical update ↗This opens an email draft. Nothing is sent automatically, and submitting a correction does not mark the rig as verified.
Plan your fixtures, explore looks and build a show in HitLight.